--. 0

Product

 [XM8567]  Illuminance Sensor for Anti-direct Light Control

XM8567

Technical Parameters

Technical parameterParameter value
BrandXUNCHIP
Illuminance measuring range0~65535Lux
Illuminance allow deviation±7%
Repeatability test±5%
Illuminance detection chipImport digital
Wavelength range380nm~730nm
InterfaceRS485/4-20mA/DC0-5V
PowerDC12~24V 1A
Running temperature-30~80℃
Working humidity5%RH~90%RH

Product Selection

    Product DesignRS485,4-20mA,DC0-5VMultiple output methods, the products are divided into the following models depending on the output method.
Product model output method
XM8567BRS485总线
XM8567M4-20mA
XM8567V5DC0-5V

Product Size

XM8567

software to test

XM8567 XM8567

How to use software?

XM8567 XM8567

Why choose this product?

XM8567 XM8567 XM8567

How to use?

XM8567

Application solution

XM8567

Product List

XM8567

Pictures

XM8567 XM8567 XM8567

Communication Protocol

    The product uses the RS485 MODBUS-RTU standard protocol format, and all operation or reply commands are in hexadecimal data. When the device leaves the factory, the default device address is 1, and the default baud rate is: for modules and non-recording instruments: 9600, 8, n, 1 (for the recorder series products, the default is: 115200, 8, n, 1).
1. Read data (Function code 0x03)
    The inquiry frame (in hexadecimal). Example of sending: To query 1 piece of data of device No. 1, the host computer sends the command: 01 03 00 00 00 01 84 0A .
Address Function code Starting address Data length Checksum
010300 0000 0184 0A
    For a correct inquiry frame, the device will respond with data: 01 03 02 02 18 B9 2E , and the response format is:
Address Function code LengthData 1 Checksum
0103 0202 18 B9 2E
    Data description: The data in the command is in hexadecimal. Taking Data 1 as an example, 02 18 converted to decimal value is 536. Assuming the data magnification factor is 100, then the true value is 536/100 = 5.36, and the others can be deduced by analogy.
2. Common Data Address Table
Configuration Address Register Address Register Description Data Type Value Range
4000100 00illuminanceRead Only0~65535
4010100 64 Model Code Read-only 0~59999
4010200 65 Total Number of Measuring Points Read-only 1~1600
4010300 66 Device Address Read/Write 1~249
4010400 67 Baud Rate Read/Write 0~6
4010500 68 Communication Mode Read/Write 1 Query
2 Active Upload4010600 69 Protocol Type Read/Write
1 MODBUS-RTU Others Unused

  For example, the range is 0~65535Lux, the analog output is 4~20mA current signal, Illuminance and current The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is Illuminance range upper limit, A1 is the lower limit of the range, B2 is current output range upper limit, B1 is the lower limit, X is the currently read Illuminance value, and C is the calculated current value. The list of commonly used values is as follows:
current(mA)IlluminanceValue (Lux) Calculation Process
40.0(65535-0)*(4-4)÷(20-4)+0
54095.9(65535-0)*(5-4)÷(20-4)+0
68191.9(65535-0)*(6-4)÷(20-4)+0
712287.8(65535-0)*(7-4)÷(20-4)+0
816383.8(65535-0)*(8-4)÷(20-4)+0
920479.7(65535-0)*(9-4)÷(20-4)+0
1024575.6(65535-0)*(10-4)÷(20-4)+0
1128671.6(65535-0)*(11-4)÷(20-4)+0
1232767.5(65535-0)*(12-4)÷(20-4)+0
1336863.4(65535-0)*(13-4)÷(20-4)+0
1440959.4(65535-0)*(14-4)÷(20-4)+0
1545055.3(65535-0)*(15-4)÷(20-4)+0
1649151.3(65535-0)*(16-4)÷(20-4)+0
1753247.2(65535-0)*(17-4)÷(20-4)+0
1857343.1(65535-0)*(18-4)÷(20-4)+0
1961439.1(65535-0)*(19-4)÷(20-4)+0
2065535.0(65535-0)*(20-4)÷(20-4)+0
    As shown in the above formula, when measuring 8mA, current current is 16387.75Lux。
  For example, the range is 0~65535Lux, the analog output is 0~5V DC0-5Vvoltage signal, Illuminance and DC0-5Vvoltage The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is Illuminance range upper limit, A1 is the lower limit of the range, B2 is DC0-5Vvoltage output range upper limit, B1 is the lower limit, X is the currently read Illuminance value, and C is the calculated DC0-5Vvoltage value. The list of commonly used values is as follows:
DC0-5Vvoltage(V)IlluminanceValue (Lux) Calculation Process
00.0(65535-0)*(0-0)÷(5-0)+0
113107.0(65535-0)*(1-0)÷(5-0)+0
226214.0(65535-0)*(2-0)÷(5-0)+0
339321.0(65535-0)*(3-0)÷(5-0)+0
452428.0(65535-0)*(4-0)÷(5-0)+0
565535.0(65535-0)*(5-0)÷(5-0)+0
    As shown in the above formula, when measuring 2.5V, current DC0-5Vvoltage is 32767.5Lux。
software for test product
After downloading, please read the readme.txt documentation

[RV1000] DEGBUG AND TEST SOFTWARE

Data and Software

 Online shop 

 Contact Online 

Email: sale@sonbest.com

TYPE: XM8567

WeChat: 13918126020

SKYPE: SOOBUU

Phone: +86-021-66862075

QQ1: 71182854 QQ2:613035997