 [XR1005-0001]  10.1-inch large screen small meteorological data recorder

XR1005-0001

Technical Parameters

Technical parameter Parameter value
Brand XUNCHIP
Temperature measuring range -30℃~80℃
Temperature measuring accuracy ±0.5℃ @25℃
Humidity measuring range 0~100%RH
Humidity accuracy ±3%RH @25℃
Illuminance measuring range 0~20 0000Lux
Illuminance allow deviation ±7%
Repeatability test ±5%
Illuminance detection chip Import digital
Wavelength range 380nm~730nm
PM2.5 range 0~999ug/m3
PM2.5 accuracy ±15% or ±10ug/m3 max @25℃
PM10 range 0~999ug/m3
PM10 accuracy ±15% or ±35ug/m3 max @25℃
Radioactivity measuring range 0~2000W/M2
Radioactivity allow deviation ±7%
Repeatability test ±5%
Radioactivity detection chip Import digital
Wavelength range 380nm~730nm
Communication Interface RS485
Default baud rate 9600 8 n 1
Power DC6~24V 1A
Running temperature -30~85℃
Working humidity 5%RH~90%RH

Product Size

XR1005-0001

Wiring instructions

Why choose this product?

XR1005-0001 XR1005-0001 XR1005-0001 XR1005-0001 XR1005-0001

How to use?

XR1005-0001

Product List

XR1005-0001

Pictures

XR1005-0001 XR1005-0001

Communication Protocol

    The product uses RS485 MODBUS-RTU standard protocol format, all operation or reply commands are hexadecimal data. The default device address is 1 when the device leaves the factory, and the module or NON-Recorder default baud rate is 9600,8,n,1 ,but data recorder default baud rate is 115200 .
1. Read data (function code 0x03)
    Inquiry frame (hexadecimal), sending example: query 1 data of 1# device, the upper computer sends the command: 01 03 00 00 00 06 C5 C8 .
Address Function Code Start Address Data Length Check Code
01 03 00 00 00 06 C5 C8
    For the correct query frame, the device will respond with data: 01 03 0C 00 7E 00 00 00 00 00 00 00 00 00 00 0D 59 , response format:
Address Function Code Length Data 1 Data 2 Data 3 Data 4 Data 5 Data 6 Check Code
01 03 0C 00 79 00 7A 00 7B 00 7C 00 7D 00 7E 0D 59
    Data description: The data in the command is hexadecimal, take data 1 as an example, 00 79 is converted to decimal value as 121, assuming the data magnification is 100, then the real value is 121/100=1.21, Others and so on.
    For illuminance, since each parameter occupies 2 bytes and the actual resolution of illuminance in the 200,000 range is lower than 10, we use 20,000 or 20,000 to express 200,000, that is The magnification is 10. For example, when the read data is 839, the actual illuminance value is 8390LUX.
2. Common data address table
Configuration Address Register Address Register Description Data Type Value Range
40001 00 00 temperature Read Only 0~65535
40002 00 01 humidity Read Only 0~65535
40003 00 02 Illuminance Read Only 0~65535
40004 00 03 PM2.5 Read Only 0~65535
40005 00 04 PM10 Read Only 0~65535
40006 00 05 Radioactivity Read Only 0~65535
40101 00 64 Model Code Read/Write 0~65535
40102 00 65 total number of measuring points read/write 1~20
40103 00 66 device address read/write 1~249
40104 00 67 baud rate read/write 0~6
40105 00 68 communication mode read/write 1~4
40106 00 69 protocol type read/write 1~10

 

software for test product
After downloading, please read the readme.txt documentation

[RV1000] DEGBUG AND TEST SOFTWARE

Data and Software