Technical Parameters

Technical parameterParameter value
Moisture Temperature range-30℃~80℃
Moisture Temperature accuracy±0.5℃ @25℃
Moisture measuring range0~100%
Moisture measuring accuracy ±3% @25℃
Communication InterfaceDC4~20mA
PowerDC12~24V 1A
Running temperature-30~80℃
Working humidity5%RH~90%RH

Product Size

YM3005

software to test

YM3005

Wiring instructions

How to use software?

YM3005

Why choose this product?

YM3005 YM3005 YM3005 YM3005

How to use?

YM3005

Application solution

YM3005 YM3005 YM3005

Product List

YM3005

Pictures

YM3005 YM3005

1. temperature and current computing relationship

  For example, the range is -30~60℃, the analog output is 4~20mA current signal, temperature and current The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is temperature range upper limit, A1 is the lower limit of the range, B2 is current output range upper limit, B1 is the lower limit, X is the currently read temperature value, and C is the calculated current value. The list of commonly used values is as follows:
current(mA)temperatureValue (℃) Calculation Process
4-30(60-(-30))*(4-4)÷(20-4)+-30
5-24.375(60-(-30))*(5-4)÷(20-4)+-30
6-18.75(60-(-30))*(6-4)÷(20-4)+-30
7-13.125(60-(-30))*(7-4)÷(20-4)+-30
8-7.5(60-(-30))*(8-4)÷(20-4)+-30
9-1.875(60-(-30))*(9-4)÷(20-4)+-30
103.75(60-(-30))*(10-4)÷(20-4)+-30
119.375(60-(-30))*(11-4)÷(20-4)+-30
1215(60-(-30))*(12-4)÷(20-4)+-30
1320.625(60-(-30))*(13-4)÷(20-4)+-30
1426.25(60-(-30))*(14-4)÷(20-4)+-30
1531.875(60-(-30))*(15-4)÷(20-4)+-30
1637.5(60-(-30))*(16-4)÷(20-4)+-30
1743.125(60-(-30))*(17-4)÷(20-4)+-30
1848.75(60-(-30))*(18-4)÷(20-4)+-30
1954.375(60-(-30))*(19-4)÷(20-4)+-30
2060(60-(-30))*(20-4)÷(20-4)+-30
    As shown in the above formula, when measuring 8mA, current current is 26.5℃。

2. soil Moisture and current computing relationship

  For example, the range is 0~100%, the analog output is 4~20mA current signal, soil Moisture and current The calculation relationship is as shown in the formula: C = (A2-A1) * (X-B1) / (B2-B1) + A1, where A2 is soil Moisture range upper limit, A1 is the lower limit of the range, B2 is current output range upper limit, B1 is the lower limit, X is the currently read soil Moisture value, and C is the calculated current value. The list of commonly used values is as follows:
current(mA)soil MoistureValue (%) Calculation Process
40.0(100-0)*(4-4)÷(20-4)+0
56.3(100-0)*(5-4)÷(20-4)+0
612.5(100-0)*(6-4)÷(20-4)+0
718.8(100-0)*(7-4)÷(20-4)+0
825.0(100-0)*(8-4)÷(20-4)+0
931.3(100-0)*(9-4)÷(20-4)+0
1037.5(100-0)*(10-4)÷(20-4)+0
1143.8(100-0)*(11-4)÷(20-4)+0
1250.0(100-0)*(12-4)÷(20-4)+0
1356.3(100-0)*(13-4)÷(20-4)+0
1462.5(100-0)*(14-4)÷(20-4)+0
1568.8(100-0)*(15-4)÷(20-4)+0
1675.0(100-0)*(16-4)÷(20-4)+0
1781.3(100-0)*(17-4)÷(20-4)+0
1887.5(100-0)*(18-4)÷(20-4)+0
1993.8(100-0)*(19-4)÷(20-4)+0
20100.0(100-0)*(20-4)÷(20-4)+0
    As shown in the above formula, when measuring 8mA, current current is 29%。
software for test product
After downloading, please read the readme.txt documentation

0

software for test product
After downloading, please read the readme.txt documentation

0

Data and Software

 Online shop 

 Contact Online 

Email: sale@sonbest.com

TYPE: YM3005

WeChat: 13918126020

SKYPE: SOOBUU

Phone: +86-021-66862075

QQ1: 71182854 QQ2:613035997